The Wiert Corner – irregular stream of stuff

Jeroen W. Pluimers on .NET, C#, Delphi, databases, and personal interests

  • My badges

  • Twitter Updates

  • My Flickr Stream

  • Pages

  • All categories

  • Email Subscription

    Enter your email address to subscribe to this blog and receive notifications of new posts by email.

    Join 717 other subscribers

Archive for the ‘VMware’ Category

Creating a bootable USB installer for ESXi on other operating systems than Windows

Posted by jpluimers on 2022/02/17

I wrote about Creating a bootable USB installer for ESXi and use it to create a bootable ESXi installation.

Just in case I ever need to do this on a non-Windows system, some links:

–jeroen

Posted in *nix, Apple, ESXi6, ESXi6.5, ESXi6.7, ESXi7, Linux, Mac OS X / OS X / MacOS, Power User, Virtualization, VMware, VMware ESXi, Windows | Leave a Comment »

ESXi: for my link archive – links about “vim-cmd vmsvc/message” (lots of interesting scripts for deployment scenarios)

Posted by jpluimers on 2022/02/16

In ESXi: on the console/ssh, when a moved VM pauses during power-on: show which VMs have messages waiting, then answer them, I searched for [Wayback] “vim-cmd vmsvc/message” – Google Search in order to see which messages were available.

That search revealed a lot more links, so here are the ones I found most interesting:

 

–jeroen

Read the rest of this entry »

Posted in ESXi4, ESXi5, ESXi5.1, ESXi5.5, ESXi6, ESXi6.5, ESXi6.7, ESXi7, Power User, Virtualization, VMware, VMware ESXi | Leave a Comment »

ESXi: for my link archive “Developing for VMware ESXi”

Posted by jpluimers on 2022/02/15

This post amends the post last week on rsync backup of your ESXi box: How to make a statically linked rsync binary « The Wiert Corner – irregular stream of stuff.

Two weeks ago, I posted about Source: ESXi: searching for “vim-cmd vmsvc/message” lead me to the “Managing ESXi Without VI Client” series of blog posts.

It got me looking more deeply in the VM-Help site, and I found [Wayback] Developing for VMware ESXi – Virtual Machine and VPS Tutorials, for which I have materialised the links below and checked their WayBack machine status.

Compiling Utilities for ESXi

Given that ESXi is not based on Linux you won’t find any installer which you could use to install any Linux components that you might want to add to ESXi. However, ESXi does make use of a number of Open Source packages such as OpenSSL, Python, and Openwsman (WS-Management). The key to compiling a utility for ESXi is creating a statically linked version of the tool. With a statically linked version, there are no dependencies on other libraries that may not be present on ESXi. The downside to this method of compiling is that the utility may be larger than a dynamically linked version. With a dynamically linked version the utility assumes that other libraries are present and can rely on subroutines within those libraries.

Compiling rsync – [Wayback] How to compile a statically linked rsync binary for ESXi
Compiling Busybox – [Wayback] How to compile Busybox for ESXi … kind of Part 1
Discussion of compiling UNFS – http://www.vm-help.com/forum/viewtopic.php?f=16&t=2280&p=10185&e=10185 (not archived in the WayBack machine nor available on-line)
Notes on compling binaries – [Wayback] Stjepan Groš – Homepage

Compiling Drivers for ESXi

Given the common misunderstanding that ESXi is Linux based, a new user often inquires about the process of copying a Linux driver to their ESXi install. This is not possible. ESXi includes a Linux driver compatibility module. This allows for Linux source code to be used to compile drivers for ESXi, but the drivers are still specific to ESXi. The following links provides some samples and notes for compiling drivers for ESXi.

Compiling a Silicon Image 3132 driver – [Archive.is] Wayback: Adding Driver Support to VMware ESXi 4 | Tip’s Notebook
Compiling a Marvell sky2 driver – [Wayback] Using a Marvell LAN card with ESXi 4 – KernelCrash

(Note: This post was initially written when ESXi 4.0 was available. As of late 2010, ESXi 4.1 has been released, and it does actually include a sky2 driver that may or may not work with various Marvell LAN chipsets. The post is still relevant (especially the comments)  if your particular Marvell chipset does not work with the sky2 driver in ESXI 4.1. Also, the post is relevant if you’re interested in porting other network drivers to ESXi)

Open Virtualization Drivers development notes

Being from the ESXi 4 and 5 era, the links seem to hold up remarkably well. Despite ESXi 3 being Linux based (see [Archive.is] VMware ESX Server – Wikipedia, the free encyclopedia), as opposed to ESXi 4 and up that run a microkernel, Linux based tools still can be used to develop tooling and drivers.

–jeroen

Posted in ESXi4, ESXi5, ESXi5.1, ESXi5.5, ESXi6, ESXi6.5, ESXi6.7, ESXi7, Power User, Virtualization, VMware, VMware ESXi | Leave a Comment »

ESXi: origin of the ESX and GSX names

Posted by jpluimers on 2022/02/10

Not sure how I bumped into the below info, as it was in one of the open tabs of a VM that I had not accessed for a long time.

Tracing back, the links can be found via Wikipedia.

Here is the post content from the 2005 thread [Archive.is] Wayback “Abbreviation ESX”:

VMware: Origin of ESX and GSX names

VMware: Origin of ESX and GSX names

STSHot Shot

535 posts since
Apr 2, 2004

2. Aug 10, 2005 6:22 AM  in response to: kimono

Re: Abbreviation ESX

ESX = Elastic or Electric Sky

GSX = Ground Sky

early days west coast cali hippy advertising thinking from the boys in the states. They dont mean’t anything and the X was added for acromyn 

Related:

–jeroen

Posted in Power User, Virtualization, VMware, VMware ESXi, VMware Server (GSX) | Leave a Comment »

ESXi: on my list to try VIC (VMware Infrastructure Client you say? Née vSphere Integrated Containers Engine)

Posted by jpluimers on 2022/02/08

On my research list: [Wayback] ESXi Host with No vCenter Server · VMware vSphere Integrated Containers 1.4 Documentation: Deploy a Virtual Container Host to an ESXi Host with No vCenter Server.

It is a small guide on [Wayback] vmware/vic: vSphere Integrated Containers Engine is a container runtime for vSphere.

vSphere Integrated Containers Engine (VIC Engine) is a container runtime for vSphere, allowing developers familiar with Docker to develop in containers and deploy them alongside traditional VM-based workloads on vSphere clusters, and allowing for these workloads to be managed through the vSphere UI in a way familiar to existing vSphere admins.

Given my virtualisation infrastructure is ESXi based, I need to contemplate on this, as there are basically two choices for me:

  • Install a docker host as a VM on the ESXi host and go all the way docker (which needs a very good thought on how many resources to allocate to the docker host)
  • Go the VIC way

Food for thought!

–jeroen

Posted in ESXi6, ESXi6.5, ESXi6.7, ESXi7, Power User, Virtualization, VMware, VMware ESXi | Leave a Comment »

Samsung 980 Pro NVMe SSD serial in ESXi is in different byte order than the sticker

Posted by jpluimers on 2022/02/03

I installed three Samsung 980 Pro NVMe SSD devices in various ESXi rigs.

This is the serial numbers that ESXi came up with:

  1. Local NVMe Disk (t10.NVMe____Samsung_SSD_980_PRO_1TB_________________E824B311B1382500)
  2. Local NVMe Disk (t10.NVMe____Samsung_SSD_980_PRO_1TB_________________782DB311B1382500)
  3. Local NVMe Disk (t10.NVMe____Samsung_SSD_980_PRO_1TB_________________6F2DB311B1382500)

ESXi presents the serial number (actually the EUI64) in reverse byte order of what is on the device labels.

I had to look up what EUI64 was, and it is a kind of UUID (see Universally unique identifier – Wikipedia), but for hardware devices:

  • World Wide Name – WikipediaEach WWN is an 8- or 16-byte number, the length and format of which is determined by the most significant four bits, which are referred to as an NAA (Network Address Authority). The remainder of the value is derived from an IEEE OUI (or from Company Id (CID)) and vendor-supplied information. Each format defines a different way to arrange and/or interpret these components. OUIs are used with the U/L and multicast bits zeroed, or sometimes even omitted (and assumed zero). Though CID has U/L set to 1.The WWN formats include:…
    • “Mapped EUI-64” formats manage to fit an EUI-64 address into an 8-byte WWN. Since the NAA is mandatory, and takes up a nibble, this represents a four-bit deficit. These four bits are recouped through the following tricks: First, two bits are stolen from the NAA by allocating NAAs 12, 13, 14, and 15 to all refer to the same format. Second, the remaining two bits are recouped by omitting the U/L and multicast bits from the EUI-64’s OUI. When reconstructing the embedded EUI-64 value, the U/L and multicast bits are assumed to have carried zero values.

    …

  • [Wayback] Base NVM Express – Part One – NVM Express

    A namespace ID (NSID) is an identifier used by a controller to provide access to a namespace (handle to a namespace). An NVMe controller may support multiple namespaces that are referenced using NSID. EUI64 (8 bytes), NGUID (16 bytes) and UUID (128-bit) are globally unique namespace identifiers defined in the Base Specification.

  • [Wayback] VMware Docs: NVMe Devices with NGUID Device Identifiers

    For NVMe devices, ESXi generates device identifiers based on the information it retrieves from the devices. Generally, the NVMe devices support identifiers in EUI64 or NGUID formats, or use both formats. NGUID is a Namespace Globally Unique Identifier that uses the EUI64 16-byte designator format.

  • [Wayback] ESXI6.7 nvme ssd issue – VMware Technology Network VMTN

    Being a software engineer, I am disturbing by the way this software create the disk ID.

    According to the following table from VMware Docs we have some case that the software will not recognize the disk or lost disks.

    ID Formats Supported by Device Device Identifier Generated by Host
    EUI64 ID Format NGUID ID Format ESXi 6.7 and earlier ESXi 6.7 Update 2
    yes yes t10.xxx_EUI64 t10.xxx_EUI64
    yes no t10.xxx_EUI64 t10.xxx_EUI64
    no yes t10.xxx_controller_serial_number eui.xxx (NGUID) as primary ID

    t10.xxx_controller_serial_number as alternative primary ID

    so what if

    1. The NVMe SSD from the same company may use the same EUI64 for every NVMe SSD on the same interface (say using an ASUS Hyper M.2 X16 PCIe 3.0×4 Expansion card with 4 identical NVMe SSD). It is possible because of bad design from the SSD manufacturer, the EUI64 are all the same for the 4 NVMe SSD, under this case, the ESXI will only recognized one of the 4 disks (since the disk will be t10.xxx_EUI64, and EUI64 are the same for all 4 NVMe SSD, The “storage” “adapters” tab did show there are 4 interfaces (adapters), but the “stroage” “devices” will only show 1 disks.
    2. Why there is no “no, no” options?

    I understand that the NVMe standard 1.3 (for ESXi 6.7) is the base of how the NVMe SSD should be designed, but I think the software should be smart enough to cover the mistakes the hardware company may make and so it can recognized most of the NVMe SSD that is available from the market.

    …

    I have the same issue in V7.0! Whatever happened to using something you know is unique like serial numbers or something based off the serial number!

    My two identical NVMe drives show up as one! Very odd how this one got through testing!

    …

    Having same issue with the Asus hyper x16 m. 2 pcie card. I have 4 Intel 660p in it and it’s only showing 1. Even when I changed the bifurcation to x4x4x4x4 for that pcie slot. It actually show nothing. When in auto it shows 1. I’m using esxi 7 though. Trying to test out VMware horizon but esxi not detecting all the nvme in the Asus adapter.

  • [Wayback/Archive.is] linux.kernel: [PATCH 0/7] Implement NVMe Namespace Descriptor Identification

    This patchset implemets NVMe Namespace Descriptor Identification as of
    NVMe 1.3. The Namespace Descriptor Identification allows a NVMe host
    to query several Namespace Identification mechanisms, such as EUI-64,
    NGUID and UUID from the target. If more than one value is set by the
    target, it can transmit all set values to the host.

  • [Wayback] OS-6042: Need to handle NVMe devices with EUI64 values (SmartOS + ZFS)

    NVMe devices with namespaces with an EUI64 value do not attach to the system. It’d be good if these did.

  • [Wayback] âš™ D19905 bhyve: Add EUI64 to NVMe device (FreeBSD)

    Add the EUI64 field (part of the Identify Namespace data) to NVMe devices to support UEFI drivers.

    The implementation will accept an IEEE Extended Unique Identifier (EUI-64) from the command line. If one isn’t provided, it will create one based on

    • The IEEE OUI reported in the Identify Controller data
    • The PCI bus, device/slot, function values
    • The Namespace ID
  • [Wayback] nvme-scsi: Use correct byte ordering for eui64 in Dev ID VPD – Patchwork
    NVME specifies an EUI64/NGUID in little-endian format, while SCSI
    specifies that the Device Identification VPD use big-endian for EUI
    formats. The current code copies this bytestream directly from the
    Identification Namespace page, meaning we just need to reverse the
    bytestream when passing it on to the VPD.

    …

    This seems to hold true for NGUID devices, but Keith just pointed out to
    me that it may not hold true for EUI64 devices. It seems like that case
    needs byte swiveling within each field. So I'll NAK for now until I can
    figure out if that's the case.

    …

    This will break existing setups that rely on VPD 0x83 for device
    identification (which I think includes older SuSE distros).
    
    And once you change the setup anyway please stop using this buggy
    SCSI emulation.

    …

  • [Wayback] A Quick Tour of NVM Express (NVMe)

    …

    • nguid, Namespace Globally Unique Identifier (NGUID) and, eui64, IEEE Extended Unique Identifier (EUI64) are assigned when the namespace is created and preserved across namespace and controller operations (e.g. reset, format).

    …

These are pictures of the devices in the same order:

Read the rest of this entry »

Posted in ESXi6.5, ESXi6.7, Hardware, NVMe, Power User, SSD, Virtualization, VMware, VMware ESXi | Leave a Comment »

ESXi: searching for “vim-cmd vmsvc/message” lead me to the “Managing ESXi Without VI Client” series of blog posts

Posted by jpluimers on 2022/02/02

Last week, I wrote about ESXi: on the console/ssh, when a moved VM pauses during power-on: show which VMs have messages waiting, then answer them.

The “vim-cmd vmsvc/message” – Google Search there lead me to this very interesting series of blog posts on managing ESXi Without VI Client.

It was written in the ESXi 4 and 5 era (for a time-frame, see [Wayback] VMware ESXi Release and Build Number History | virten.net) where VIC – the [Wayback] VMware Infrastructure Client, later named VC:  [Wayback] vSphere Client – ruled.

The series content holds remarkably well now that VIC/VC got first replaced by the [Wayback] vSphere Web Client (often called [Wayback] vSphere HTML 5 Client and started out of the [Wayback] ESXi Embedded Host Client fling).

Anyway, here are the posts in the series:

  1. [Wayback] Managing ESXi Without the VI Client – Part 1 – Virtual Machine and VPS Tutorials – initial setup and creating a VM
  2. [Wayback] Managing ESXi Without the VI Client – Part 2 – Virtual Machine and VPS Tutorials – add a license key, enable VM automatic startup and shutdown and unregister a VM
  3. [Wayback] Managing ESXi without the VI Client – Part 3 – Virtual Machine and VPS Tutorials – create a virtual switch and configure a firewall VM
  4. [Wayback] Managing ESXi without the VI Client – Part 4 – Virtual Machine and VPS Tutorials – install an update for ESXi
  5. [Wayback] Managing ESXi Without VI Client – Part 5 – Virtual Machine and VPS Tutorials – creating a datastore, then moving a VM between datastores

–jeroen

Posted in ESXi4, ESXi5, ESXi5.1, ESXi5.5, ESXi6, ESXi6.5, ESXi6.7, ESXi7, Power User, Virtualization, VMware, VMware ESXi | Leave a Comment »

ESXi: editing /etc/vmware/hostd/vmInventory.xml to fix the datastore UUID for unavailable VMs part 2

Posted by jpluimers on 2022/02/01

I started my post ESXi: editing /etc/vmware/hostd/vmInventory.xml to fix the datastore UUID for unavailable VMs with

In case I ever need this on ESXi: Insights into the VMware inventory files (vmAutoStart.xml and vmInventory.xml on ESXi; inventory.vmls on VMware Workstation/Player)

Since almost all of my blog is about things I bumped into in real life, this post was a preparation because I kind of expected this to indeed happen, and it did.

Below are the screenshots and steps I took. Of course it is an N=1 experience, so your situation might differ, but I tried to be thorough and not miss any steps.

Read the rest of this entry »

Posted in ArchiveTeamWarrior, ESXi6, ESXi6.5, ESXi6.7, ESXi7, Internet, InternetArchive, Power User, Virtualization, VMware, VMware ESXi, WayBack machine | Leave a Comment »

Some links on using and updating Let’s Encrypt certificates for internal servers

Posted by jpluimers on 2022/02/01

Sometimes it is easier to have current and public CA signed TLS certificates for internal servers than to setup and maintain an internal CA and register it on all affected browsers (including mobile phones).

One of my reasons to investigate this is that Chrome refuses to save credentials on servers that have no verifiable TLS certificate, see my post Some links on Chrome not prompting to save passwords (when Firefox and Safari do) about a week ago.

Below are some links for my link archive that hopefully will allow me to do this with Let’s Encrypt (msot via [Wayback/Archive] letsencrypt for internal servers – Google Search):

Read the rest of this entry »

Posted in Cloud, Cloudflare, Development, Encryption, ESXi6, ESXi6.5, ESXi6.7, ESXi7, Fritz!, Fritz!Box, Fritz!WLAN, Infrastructure, Internet, Let's Encrypt (letsencrypt/certbot), Power User, Security, Software Development, Virtualization, VMware, VMware ESXi, Web Development | Leave a Comment »

ESXi: on the console/ssh, when a moved VM pauses during power-on: show which VMs have messages waiting, then answer them

Posted by jpluimers on 2022/01/27

First the script that display messages for all virtual machines, vim-cmd-display-messages-for-all-VMs.sh:

#!/bin/sh
vmids=`vim-cmd vmsvc/getallvms | sed -n -E -e "s/^([[:digit:]]+)\s+((\S.+\S)?)\s+(\[\S+\])\s+(.+\.vmx)\s+(\S+)\s+(vmx-[[:digit:]]+)\s*?((\S.+)?)$/\1/p"`
for vmid in ${vmids} ; do
    powerState=`vim-cmd vmsvc/power.getstate ${vmid} | sed '1d'`
    name=`vim-cmd vmsvc/get.config ${vmid} | sed -n -E -e '/\(vim.vm.ConfigInfo\) \{/,/files = \(vim.vm.FileInfo\) \{/ s/^ +name = "(.*)",.*?/\1/p'`
    vmPathName=`vim-cmd vmsvc/get.config ${vmid} | sed -n -E -e '/files = \(vim.vm.FileInfo\) \{/,/tools = \(vim.vm.ToolsConfigInfo\) \{/ s/^ +vmPathName = "(.*)",.*?/\1/p'`
    echo "Messages for VM with id ${vmid} which has power state ${powerState} (name = ${name}; vmPathName = ${vmPathName})."
    vim-cmd vmsvc/message ${vmid}
done
exit 0

It is very similar to vim-cmd-reload-all-VM-vmx-configurations.sh from Source: ESXi: reloading all virtual machines from their (potentially) vmx files.

Messages I know either equal “No message” or are about “This virtual machine may have been moved or copied.“

If there is no available message, then you always get the stock message No message., so this is something you can use as a check in scripts.

Read the rest of this entry »

Posted in *nix, *nix-tools, ArchiveTeamWarrior, ash/dash, ash/dash development, Development, ESXi6, ESXi6.5, ESXi6.7, ESXi7, Power User, Scripting, Software Development, Virtualization, VMware, VMware ESXi | Leave a Comment »